Diyaplus Disinfectant with Citric Acid for Hemodialysis Machines
DİYAPLUS is designed for closed system hot circulations cleaning of hemodialysis device. Besides its disinfection feature, it also provides perfect removing of blood residues and calcium carbonate precipitates can occur in hemodialysis device
FEATURES
- It allows the cleaning and disinfection of the device by applying heat disinfection programs in hemodialysis devices with volumetric mixing system. Dyaplus solution has bactericidal, fungicidal and virucidal effect.
- Because of its ecidic feature, it removes precipitates of calcium and magnesium carbonate which can occur in the devices.
- Consists of all-natural ingredients. Environmentally friendly. %100
- The product is buffered in order to increasse stability and effectiveness and its pH is set to 2,4 - 2,5.
- Non-toxic and not flammable.
- It provides disinfection and decalcification at one-stop.
USAGE FIELD
Hemodialysis devices with volumetric mixing system.
INGREDIENTS
Every 100g cocentrated dicinfectant contains 20 g of citric acid anhydrate and malic acid, lactic acid, buffering agent additionnally dissolved in water (R.O)
MICROBIOLOGICAL EFFECT
In closed system circulating heat disinfection program of hemodialysis devices; bactericidal (gram positive , gram negative bacteria, methicilin -resistans to Camphylobacters) fungicide (molds and yeasts), virucidal (HBV, HCV, HIV, Adeno, Rota, Papova viruses) are effective above 600C.
METHOD OF USE
CONCANTRATED DIYAPLUS solution is automotically sucked from the pipette of hemodialysis devices; with volumetrix mixing system. In hemodialysis devices 600C., it is used with disinfection programs with citric acid. At the end of the cleaning process, the final washing of the system must be made with RO water for at least 10 minutes. Refer to the device's user manual for the devices with integrated cleaning and disinfection program.
WARNINGS
- Do not use in hand, face of food cleaning.Do not drink.
- When using with the hemodialysis devices; concentrated disinfectant must be diluted in proportion that is specified in the operating instructions.
- Follow the instructions for cleanin and disinfection of hemodialysis device.
It is irritant and abrasive.
- When using concentrated disinfectant or a diluted solution, avoid contact with skin or eyes. In case of a splash to the eye, rince your eyes immediately with plenty of water.
- Keep it out reach of children and in original packaging.
- Discard the remaining concentrates after diluting it with water.
- Disinfectant should be used by trained personnel.
- Avoid contact with surfaces that react wiith acid such as aluminum, marble, Plexiglas etc.
- Consult your physician if you notice unexpected effects with the product.
- The product is manufactured in accordance with Medical Device Directive 93/42 /EEC and ISO 13485:2007 standard.
STORAGE CONDITIONS
Usage time is 2 years from date of manufacture. Should be stored at 15-250C in original package and away from sun light.